GE 369B1859G0022 Medium and high voltage motor protection relay
Specific Parameters
- Electrical Parameters
- Supply Voltage: 100-240V AC/DC (wide-range input), 24V DC (optional)
- Power Consumption: ≤15W under normal operation, ≤20W at maximum load
- Measurement Range:
- Current: 0.1-6300A (via CT input, CT ratio programmable)
- Voltage: 0-600V AC (line voltage/phase voltage)
- Measurement Accuracy:
- Current: ±0.5% full scale
- Voltage: ±0.5% full scale
- Power: ±1.0% full scale
- Protection Functions:
- Overcurrent protection (inverse time/definite time), short-circuit protection, ground fault protection
- Locked rotor protection, phase loss protection, overvoltage/undervoltage protection, temperature protection (PTC/RTU input)
- Communication Interfaces: 1×RS485 (Modbus RTU/TCP), 1×Ethernet (IEC 61850)
- Output Circuits: 4×Form-C relay outputs (250V AC/30V DC, 5A resistive load)
- Input Circuits: 8×digital inputs (dry contact/active signal), 2×analog inputs (4-20mA)
- Environmental Parameters
- Operating Temperature: -25°C to 70°C
- Storage Temperature: -40°C to 85°C
- Relative Humidity: 5% to 95% (non-condensing, no dew formation)
- EMC Immunity: Compliant with EN 61000-6-2 (industrial grade), EN 61000-6-4
- Vibration Resistance: 10-500Hz, 5g acceleration (compliant with IEC 60068-2-6)
- Shock Resistance: 15g acceleration, 11ms duration (compliant with IEC 60068-2-27)
- Mechanical Parameters
- Dimensions: 96mm (W) × 96mm (H) × 140mm (D)
- Weight: Approximately 500g
- Mounting Method: Panel-mount, 35mm standard DIN rail mounting
- Protection Class: IP54 (front panel), IP20 (rear terminals)
- Housing Material: Flame-retardant ABS engineering plastic (UL 94 V-0 grade)
- Terminal Type: Spring-loaded crimp terminals (compatible with 14-22 AWG wires)
Product Performance
369B1859G0022 adopts a 16-bit high-precision A/D converter with a current sampling rate of 10kHz, ensuring fault response time ≤10ms, which can quickly cut off the fault circuit to avoid motor damage. It supports 10 sets of custom protection logic, and realizes flexible configuration of protection parameters through buttons or software configuration, adapting to different motor types and operating conditions.
Integrated with motor health monitoring function, it real-time calculates insulation resistance, bearing temperature trend and load rate, generates operation reports and fault recording (up to 100 event records), supporting data traceability before and after faults. Communication interfaces support dual-network redundancy with data transmission delay ≤50ms, enabling seamless connection with GE PACSystems or third-party SCADA systems.
Wide temperature design and IP54 protection class ensure stable operation in harsh industrial environments, with mean time between failures (MTBF) ≥200,000 hours, supporting online calibration and firmware upgrade without power-off during maintenance.















There are no reviews yet.