GE 369B1843G5009 Protection Relay

GE 369B1843G5009 is an industrial-grade power system protection relay, specifically designed for transformers, motors, and transmission lines in medium and low-voltage distribution networks. Its core function is to real-time monitor electrical parameters such as current, voltage, and frequency of power equipment, identify fault types including overcurrent, overvoltage, undervoltage, and overload through built-in protection algorithms, and quickly trigger tripping or alarm actions. It also has electrical parameter measurement, data recording, and remote communication functions, which can be connected to a power monitoring system (SCADA) to provide accurate protection for the safe operation and fault troubleshooting of distribution equipment, serving as a core protection component in medium and low-voltage distribution automation systems.​

GE 369B1843G5009 Protection Relay

Specific Parameters​

  • Power Supply Parameters

Supply Voltage: AC/DC 85-265V​

Power Frequency: 50/60Hz (auto-adaptive)​

Rated Power Consumption: ≤15W (normal operation), ≤5W (standby state)​

Power Isolation: 2500Vrms (for 1 minute continuously, power and input signal terminals)​

  • Protection Function Parameters

Protection Types: Overcurrent Stage I (instantaneous), Overcurrent Stage II (definite time), Overcurrent Stage III (inverse time), Overvoltage, Undervoltage, Frequency Abnormality (overfrequency/underfrequency)​

Overcurrent Protection Range: 0.1-10In (In is rated current, configurable)​

Overcurrent Stage I Operation Time: ≤0.05s (when setting current ≥10In)​

Overvoltage Protection Range: 105%-120%Un (Un is rated voltage, configurable)​

Undervoltage Protection Range: 70%-90%Un (configurable)​

Frequency Protection Range: 45-55Hz (configurable, operation error ±0.02Hz)​

  • Measurement Parameters

Measurement Objects: Three-phase current, three-phase voltage, power (active/reactive), power factor, frequency, electrical energy (forward/reverse)​

Current Measurement Accuracy: ±0.2%FS (within rated current range)​

Voltage Measurement Accuracy: ±0.2%FS (within rated voltage range)​

Power Measurement Accuracy: ±0.5%FS (when power factor 0.8-1.0)​

  • Communication Parameters

Supported Protocols: Modbus RTU (RS485), IEC 61850, DNP3.0​

Communication Interfaces: 1 RS485 interface (half-duplex, baud rate 1200-115200bps configurable), 1 Ethernet port (10/100Mbps auto-adaptive)​

Data Recording Capacity: ≥1000 fault records (including fault type, time, electrical parameters)​

  • Environmental Parameters

Operating Temperature Range: -40°C to +70°C​

Storage Temperature Range: -40°C to +85°C​

Relative Humidity: 5% to 95% (non-condensing, when temperature ≤40°C)​

Protection Class: IP54 (panel), IP20 (terminal chamber)​

EMC Immunity: Complies with IEC 61000-6-2 industrial environment EMC standard​

  • Physical Parameters

Mounting Type: Panel-mounted (compatible with standard 19-inch rack)​

Dimensions (L×W×H): 144mm×144mm×180mm (excluding terminals)​

Weight: Approximately 1.2kg​

Output Contacts: 2 sets of DPDT (double-pole double-throw) relay contacts, rated current 10A@250V AC​

Product Performance​

  • High-Precision Protection Operation: Current and voltage measurement accuracy reaches ±0.2%FS, and overcurrent instantaneous operation time is ≤0.05s, which can accurately identify faults and respond quickly to prevent equipment damage caused by fault expansion.​
  • Multi-Protection Function Integration: Supports 6 types of core protection functions including overcurrent, overvoltage, undervoltage, and frequency abnormality simultaneously, no additional protection modules required, simplifying the design of distribution system protection schemes.​
  • Strong EMC Immunity: 2500Vrms high isolation design between power supply and signal terminals, combined with an electromagnetic shielding shell, can resist surges, harmonics, and electromagnetic radiation interference in distribution sites, with protection action false operation rate ≤0.01 times/year.​
  • Wide Environmental Adaptability: The operating temperature range of -40°C to +70°C covers alpine and high-temperature areas, and the IP54 protection class can resist dust and splashing water, adapting to complex environments such as outdoor distribution rooms and industrial workshops.​
  • Intelligent Data Management: Built-in ≥1000 fault records function, which can store electrical parameter snapshots when faults occur, supporting data export through communication interfaces to assist operation and maintenance personnel in tracing fault causes and shortening troubleshooting time.​




    Customers reviews